A Type C cavity wall and floor membrane forms a waterproof inner lining. Any water that gets through the structure is collected in the cavity behind it, directed to a sump and pumped away.
Because the system doesn’t rely on stopping water at the surface, it suits deep basements, high water tables and spaces that need a dry, habitable finish.

A drained system that manages water rather than holding it back: studded membranes on the walls and floor channel any water to a sump, where it is pumped away.
We design the membrane layout, drainage, sump position and pumping, including dual pumping where the layout calls for it.
Wall and floor membranes are fixed with sealed laps and junctions, often over an anti-lime treatment to the concrete.
Perimeter channels carry water to the sump, with access ports for maintenance.
Sump chambers and pump stations are sized for the basement and its groundwater conditions.
Compare the ways BS 8102 protects a basement, and where we’ve used each one.
Simplified section through a basement wall. Not to scale.
A studded membrane lines the walls and floor. Any water that gets through runs down the cavity to a channel and a sump, and a pump takes it away.

A Grade 3 basement under BS 8102, with a swimming pool, external deck and plant room, for a detached period house.
“We found the Renlon team to be helpful and the operatives were diligent in ensuring that their installation was carried out to the highest standards to ensure that no further ingress ensued. I would have no hesitation in using Renlon again.”




Quick answers from our surveyors. Still stuck? Email survey@renlon.com and a qualified surveyor replies.
Yes. Drainage channels and pumps need regular servicing so the system keeps working. We design in access ports so channels can be maintained.
We are approved by the leading manufacturers. Recent projects used BBA-certified Delta MS 500 wall membrane and MS 20 floor membrane with Delta Channel perimeter drainage.
Any water that gets through the structure runs down the cavity behind the membrane into perimeter channels. The channels take it to a sump, and the pump removes it. Where the layout calls for it, we design in dual pumping.
The membranes themselves are slim studded sheets, but a finish usually goes in front of them, so some space is lost. Where every millimetre counts, a Type A system may suit better, and our surveyor will explain the trade-off.