Type A waterproofing systemRenStrength™ is our own Type A system for basements, vaults and slabs where the existing waterproofing has failed. Where suitable, it goes straight over the old system and strengthens the structure in the same slim application.
Specifying it? Technical downloads

Drag to compare before and after.
Only from RenlonFixes failed waterproofing over what's already there, where suitable.
What most remedial jobs start with.
Where suitable, RenStrength™ goes straight over the existing system. There is far less to break out and take away before the new work starts.

The data you need to specify it, and a specialist who takes responsibility for the waterproofing design.

Where the existing render or screed is sound, RenStrength™ keeps it in place and goes over it.

Four components are built up in one application, so the wall or soffit is waterproofed and strengthened without giving up floor space.
Scroll through each component below.
Stops persistent leaks, even under pressure, so the next coats can go on.

Forms a self-healing waterproof barrier.

A high-strength render for a hard-wearing finish.

Improves resistance to cracking and strengthens the structure.


There’s a version of RenStrength for each of these surfaces. Your surveyor checks the structure on the survey and specifies the one that suits it.
Four kinds of surface, each with its own version
| Surface | It goes over | Why it suits |
|---|---|---|
| Concrete walls | Existing concrete. | Where no repairs or fairing coats are needed. |
| Existing render | Render that is already on the wall. | The old render doesn’t need hacking off. |
| Vaults and soffits | Porous or poor soffits such as clinker, Yorkstone or filler-joist concrete. | The mesh also strengthens a fragile soffit. |
| Slabs and screeds | Existing slabs or fully bonded screeds. | It avoids taking the screed up. |
Case study · North LondonBasement and pool for a North London family homeA Grade 3 basement under BS 8102, with a swimming pool, external deck and plant room, for a detached period house.Read the case studyQuick answers from our surveyors. Still stuck? Email survey@renlon.com and a qualified surveyor replies.
Often not. RenStrength has variations made to go over existing concrete, existing render and existing slabs or fully bonded screeds. The surface must be sound, so any debonded patches are cut out and replaced first. Your surveyor confirms what can stay on the survey.
On walls and soffits, about 12 mm in total. Over slabs it is a 30 mm or 50 mm application, depending on the variation.
Yes. It is a barrier system bonded to the structure, which BS 8102 calls Type A. Our surveyors design the waterproofing to BS 8102:2022 and say whether it needs to work alongside other protection.
The system includes a carbon or glass-fibre mesh, which improves resistance to cracking and structural degradation. It can also encapsulate steel beams. Any structural calculations are approved by a structural engineer.
It needs a sound, stable substrate and can’t be applied below +5 °C. Active leaks are stopped first. Where the structure isn’t suitable, the surveyor will recommend another system.
Yes. It is installed only by Renlon Approved Installers, with our own 10-year guarantee on qualifying works.