BS 8102 explained in plain English

The British Standard for protecting below-ground structures sets out how waterproofing should be designed. Here is what it means for your project.

The short answer

BS 8102:2022 is the code of practice for protecting below-ground structures against water from the ground. It asks you to decide how dry the space must be (the grade), then design one or more types of protection (A, B or C) to achieve it, with a waterproofing specialist involved from the start.

The three grades: how dry the space must be

  • Grade 1: some seepage and damp areas are tolerable, for example a car park.
  • Grade 2: no water penetration, but some damp may be tolerable and ventilation may be needed, for example a plant room.
  • Grade 3: no water penetration, with ventilation, dehumidification or air conditioning, for example living space, offices or storage of sensitive items.

The three types of protection

  • Type A, barrier protection: a waterproof layer bonded to the structure.
  • Type B, structurally integral protection: waterproof concrete designed into the structure.
  • Type C, drained protection: a cavity membrane that collects water and drains or pumps it away.
GroundwaterGround levelDry basementSUMP & PUMPWallCavity membrane

Simplified section through a basement wall. Not to scale.

Type C

Drained protection

A studded membrane lines the walls and floor. Any water that gets through runs down the cavity to a channel and a sump, and a pump takes it away.

Best for

  • Deep basements and pools
  • Grade 3 living space
  • Structures that may move or crack
On our sitesNorth London family home: Delta membranes and two dual-pumping systems around a pool.Read the case study

The three types of protection in BS 8102, and the two combined.

What the standard asks of the design

The design should consider the ground and water conditions, the risks if the system fails, and how the space will be used and maintained. For higher-risk basements it often means combined protection, using two types together.

It also expects a waterproofing specialist to be part of the design team early, so details are worked out before construction rather than on site.

How Renlon helps

We provide full design and installation of Type A and Type C systems to BS 8102:2022, with £10m professional indemnity insurance as the specialist waterproofing designer, and help project teams align decisions with insurer requirements and Building Safety Act obligations.

Not sure what you need?A qualified surveyor will find the cause and tell you straight.
Ask a surveyor

Related service: Basement & Structural Waterproofing